2026-08-10 · 4 min
Problem: Heat Spreader Flatness Fails After Anodize — Mask the Thermal Face
Problem: Al6061 heat spreaders meet thickness in-process, then after clear/black anodize the thermal face bows past 0.05 mm and TIM contact dies.
Root cause: whole-part anodize with no masking; powder coat chosen for cosmetics even though film thickness hurts conduction.
Fix: as-machined thermal face + anodize only non-contact sides; put flatness and cutout tolerances on the PDF; sample flatness before ship.
Lead sketch: Standard ≈ 8–10 days with finish; skip powder on contact plates.
Upload STEP + PDF on the quote page — pick finish carefully, then open the electronics industry page for EMI / cover siblings.